o
As the colours of the wires in the appliance’s mains lead may not
correspond with the coloured markings identifying the terminals
in your spur box, please proceed as follows:
The
brown wire
must be connected to the terminal marked “L”
(live), or coloured
red
.
The
blue wire
must be connected to the terminal marked “N”
(neutral), or coloured
black
.
The
green and yellow wire
must be connected to the terminal
marked “E” (earth), or by the earth symbol, or coloured
green
and yellow
.
o
When the connection is completed, no stray strands or cut wire
should be present. The cord clamp must be secured over the
outer sheath.
Positioning
o
It is advisable that your appliance is only installed in a location
where the ambient temperature of the room, corresponds with
the climate classification that is stated on the rating plate of your
appliance. Your appliance may not function correctly if the
ambient temperature falls outside of the following ranges.
Climate classification Appropriate ambient temperature
SN
+10 to +32 degrees centigrade
N
+16 to +32 degrees centigrade
ST
+18 to +38 degrees centigrade
T
+18 to +43 degrees centigrade
o
Positioning the appliance requires two people in order to avoid
injuries or damage to the appliance.
o
Keep a minimum of 60 mm between your refrigerator and the
back wall. There should also be a gap of 50 mm either side. If
there is insufficient space this can create the sound of vibration,
weakening of the refrigerator’s power and a waste of electricity.
For the overall space required to use the appliance see the
diagram below:
23
Summary of Contents for BR190BL-W
Page 1: ...d yo BR190BL W 375 Litre frost free fridge freezer...
Page 29: ...29...
Page 30: ...30...
Page 31: ...31...
Page 32: ......