37
Baumer_HMG161_II_DE-EN (19A1)
MB115 - 11055726
10
Technical data
10
Technical data
10.1
Technical data - electrical ratings
•
Voltage supply:
9...30 VDC
•
Consumption w/o load:
≤100 mA (per interface SSI)
≤250 mA (per interface bus)
•
Initializing time:
≤200 ms after power on
•
Interfaces:
SSI, Profibus-DP V0, CANopen®, DeviceNet
•
Function:
Multiturn
•
Transmission rate:
9.6...12000 kBaud (Profibus)
10...1000 kBaud (CANopen®)
125...500 kBaud (DeviceNet)
•
Profile conformity:
Profibus-DP V0
CANopen® CiA DSP 406 V 3.0
Device Profile Encoder V 1.0
•
Device adress:
Rotary switch in bus cover
•
Steps per turn:
8192 / 13 bit
•
Number of turns:
≤65536 / 16 bit
•
Additional output signals:
Square-wave TTL (RS422)
Square-wave HTL
•
Incremental output:
2048 pulses per revolution
•
Sensing method:
Optical
•
Code:
Gray (version SSI)
•
Code sequence:
CW default
•
Inputs:
SSI clock (version SSI)
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Programmable parameters:
Depending on the selected absolute interface
•
Diagnostic function:
Position or parameter error
•
Status indicator:
DUO-LED integrated in bus cover
•
Approval:
CE, UL approval / E256710