MOUNTING / MOUNTING THE SPRING DISK COULING TO THE ENCODER
7/21
MB249EN - 11171701, 16A3, Baumer_PMG10-PROFINET_II_EN
4.
MOUNTING
4.1
Mounting the spring disk couling to the encoder
We recommend using the Baumer Hübner spring disk coupling K 35, see
, available as accessory� When other couplings are used pay attention to manufactu-
rer‘s notes�
4.2
Mounting to drive shaft
)
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error�
High runout of the drive shaft can cause vibrations, which can shorten the lifetime of
the encoder�
» Lubricate drive shaft!
»
Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
M
t
= 100 Ncm
8
7
6
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
2�5 mm
10 mm