Troubleshooting and fault correction
Operation manual
b maXX
BM4100 (NWR)
Document no.: 5.04052.09
97
9
P203
Error Proprog communication
P0204
Error in function or option modules
Error No.
Meaning
Reaction
Troubleshooting
32
Timeout protocol
adjustable Restart
BM4100 (NWR)
33
Protocol structure
adjustable
34
Wrong module type
adjustable Contact Baumüller Nürnberg GmbH
35
Too many data in the telegram
adjustable
36
Not enough data in telegram
adjustable
37
Invalid operand
adjustable
38
Invalid memory type
adjustable Test RAM
39
Invalid operand address
adjustable Enter valid address
40
Value less than the minimum value
adjustable Check and adjust data set
41
Value greater than the maximum value
adjustable
42
Parameter is write-protected
adjustable
43
Parameters in this operation state not writable
adjustable Check operating condition and parameterization
44
Invalid parameter value
adjustable Enter with a valid value
45
Communication error
ProDrive
↔
controller
adjustable Establish connection again or set parameter P0290 to
0.
46 to 47
reserved, not assigned = 0
Error No.
Meaning
Reaction
Troubleshooting
48
Error in function module A
3rd level
error
see
Error in function module A to E
3rd level)
49
Error in function module B
50
Error in function module C
51
Error in function module D
52
Error in function module E
53
Error in option module G
54
Error in option module H
55 to 58
reserved, not assigned = 0
59
Timeout when waiting for the RST signal of the
slaves
IS
Restart
BM4100 (NWR)
60
CRC error in SPI transmission
Module
f
controller
adjustable Error indicates high EMC interferences; please reduce
these.
Contact Baumüller Nürnberg GmbH.
61
CRC error in SPI transmission
Controller
f
module
adjustable
62 to 63
reserved, not assigned = 0
Summary of Contents for b maXX 4100 Series