Connection diagrams
Operation manual
b maXX
BM4100 (NWR)
Document no.: 5.04052.09
Baumüller Nürnberg GmbH
80
7.18
7.18.2 Requirements for the screwing (UL)
in case you consider UL 508 C: refer to the torques specified in
X11
Max. cable-Ø
Connection technology
Loading
BM4135
BM4145
BM4163
1.5 - 2.5 mm
2
plug-in contact
X11-1 to X11-5:
H07 to 1000 V
see
A: X1 to C: X1
1)
Cable-Ø
Connection technology
Load capacity
BM4135
BM4145
BM4163
0.75 - 2.5 mm
2
plug-in contact
X1-1, X1-2 and X1-3:
H07 to 1000 V
max.
1.0
A
D: X1
Cable-Ø
Connection technology
Load capacity
(SELV/PELV)
BM4135
BM4145
BM4163
0.75 - 1.5 mm
2
plug-in contact
X1-5 to X1-10:
in case you consider UL
508 C: max.
1.0
A
NOTE
Further information according the function module BM4-F-DIO/FIO-xx are to be taken
from the manual BM4-F-DIO/FIO-xx.