Environmental condition
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
Baumüller Nürnberg GmbH
232
9.2
9.2
Environmental condition
If the prescribed environmental conditions are adhered to, then the device is mainte-
nance-free. For the prescribed environmental conditions, refer to
The most important prescribed environmental conditions are:
m
Dust-free environmental air
m
Temperature: Min.
5 °C to max. +55 °C
m
Relative humidity:
5 % to 85 %, no condensation
m
Installation altitude: From 1000 m and higher derating
9.3
Inspection intervals - maintenance notes
Preventive maintenance is prescribed to keep the device in an optimum operating condi-
tion and ensure a long service life. It is recommended to have inspections performed reg-
ularly by qualified personnel.
Daily
inspection:
Basic check points as to whether discrepancies have occurred during operation:
m
Does the motor work as desired?
m
Is the operating environment normal?
m
Is the cooling system working normally?
m
If an unusual vibration or noise is noticed during operation.
m
Does the motor overheat during operation?
Regularly sched-
uled inspection:
Before checking, switch off the input voltage and wait until the device's capacitors have
discharged.
DANGER!
Risk of fatal injury from electrical current!
Therefore:
m
Switch off voltage before performing work!
m
Only qualified personnel may mount, install and maintain the devices.
m
Please remove all metallic objects worn, such as watches or rings, for example,
before beginning to work on the device.
m
Only insulated tools are permitted.