Electrical data basic units
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
Baumüller Nürnberg GmbH
68
3.4
3.4.1.3 Electrical data BM553X universal units
m
Without charging resistor BM553X-X
T
/BM553X-X
G
/BM553X-X
I
BM5
5
3
2
BM5
5
3
3
BM5
5
3
4
BM5
5
3
5
Rated input power
1)2)
13.3 kVA
16.8 kVA
26.3 kVA
36.7 kVA
Rated input current
1)2)
(I
eff
)
19.2 A
24.2 A
38.0 A
53.0 A
Total harmonic distortion input current (THD
I
)
1)2)
60 %
54 %
57 %
57 %
Max. input current
2)
(I
eff
)
37.0 A
45.0 A
71.0 A
71.0 A
Rated DC link voltage
1)
(U
DC
)
540 V
DC
DC link capacitance (internal)
940
F
1230
F
1640
F
2000
F
DC link discharging time (internal DC link capacitance)
140 s
210 s
280 s
340 s
DC link capacitance (external), permitted
Max. 20 mF
Waiting period between two switching-on operations
None
Output voltage
1)3)
(U
AC
)
3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
10)
0 Hz to 450 Hz
Rated output current
1)5)6)7)12)
(I
AC
)
at 4 kHz
4)
22.5 A
30.0 A
45.0 A
60.0 A
Rated output current
1)5)6)7)12)
(I
AC
)
at 8 kHz
4)
18.0 A
24.0 A
36.0 A
48.0 A
Output peak current
1)5)6)8)12)
(I
AC
)
at 4 kHz
4)
45.0 A
60.0 A
90.0 A
90.0 A
Output peak current
1)5)6)8)12)
(I
AC
)
at 8 kHz
4)
36.0 A
48.0 A
72.0 A
72.0 A
Max. peak current period
8)
60 s
Power supply DC link terminals
9)
Max. 10.0 kW
Brake resistor current, permitted (Î)
Max. 36.0 A
Max. 50.0 A
Brake resistor, external
22
16
Brake resistor threshold (Û)
780 V
Brake resistor peak power
29 kW
40 kW
Permitted continuous brake resistor power external
10 kW
Power loss referring to power input
300 W
390 W
600 W
840 W
Power input referring to control voltage
58 W
Current of the integrated brake control
Max. 1.0 A
Max. 8.0 A
11)
Summary of Contents for b maXX 5500