Cabling
y
To suppress noise emission outside the converter always screen
all
connected cables. If the screen-
ing attenuation of the switch cabinets is sufficient (see limit values of radio disturbance emissions
according to EMVG (german EMC law) for your plant) and the EMC inside the switch cabinet is guar-
anteed (this you may presume when all project planning notes given in this chapter are observed)
the control leads may be mounted unshielded.
Also observe the items in Chapter ”Screening”.