Installation
40
Basic Supply Unit BUG 622, 623
5.94034.07a
Baumüller Nürnberg GmbH
y
Sub-unit terminal X99AB
5.6
Accessories
y
Fuses
y
EMC
on requirement available:
-
EMC Filter
-
shielded cables
-
shield clamps
Terminal no..
Assignment
1, 2
Ready for use (SELV / PELV)
Relay output,: ready for use supply converter
24 V 0.5 A max.
3, 4
Forewarning (SELV / PELV)
Relay output: Forewarning supply converter
24 V 0.5 A max
5
+ Reset with 24-V-Signal (SELV / PELV)
Error message reset input of the supply converter
(potential-free optocoupler input, 8 ... 15 mA)
6
Ground reset (SELV / PELV)
Error message reset reference point of the supply converter
(potential-free optocoupler input)
BUG 622
BUG 623
Semi-conductor fuses
Part no.
80 A / 1000 V
19008531
100 A / 1000 V
19008526
Size according DIN 43620
0
0
mains fuses
35 A medium time-lag
only with reduced cross section