Three-phase synchronous motors DSC1-045-100
Technical alterations reserved
11/2016
DSC1-045-100
10
Baumüller Nürnberg GmbH
1.4.3.
Specifications for required coolant volume flows
Motor type
Volume flow
[l/min]
Pressure
decrease
15 % [bar]
Heating
[K]
Max. coolant pressure
[bar]
Connection
(G internal thread)
DSC1-071K64W
5
0.33
3
6
stainless steel tube
Ø8x1
DSC1-071S64W
5
0.4
5
6
stainless steel tube
Ø8x1
DSC1-071M64W
5
0.5
6
6
stainless steel tube
Ø8x1
Motor type
Volume flow
[l/min]
Pressure
decrease
15 % [bar]
Heating
[K]
Max. coolant pressure
[bar]
Connection
(G internal thread)
DSC1-100K64W
5
0.34
3
6
stainless steel tube
Ø8x1
DSC1-100S64W
5
0.4
5
6
stainless steel tube
Ø8x1
DSC1-100M64W
5
0.46
7
6
stainless steel tube
Ø8x1
Controlling the feed valve individually is possible, depending on the motor temperature measured by the
temperature sensor.
Note:
The given cooling volume flows relate to the highest rotary speed of the relevant motor lengths.
It is possible to make an individual cooling unit evaluation on the basis of the motors power loss
(P
V
= P
N
/
η
N
– P
N
). The cooling unit should be scaled so that its cooling performance matches the motor power
loss and so that 100% of the waste heat is diffused by the unit.
Sufficient quantities of additives for corrosion and germ protection must be mixed in. The additive type and
dosage are based on recommendations from the additive manufacturer and the prevailing ambient conditions.
A lowering of the specific heating capacity leads to an output reduction in relation to the mixing ratio which
should be enquired at the manufacturer.
1.4.4.
Materials in the motor that make contact with the product
The following materials that make contact with the medium are used in the motor:
Cooling system: stainless steel
Water connections: According to standard, the motors are supplied with a stainless steel tube Ø8x1 without
additional connection technology. The water connection with the John Guest - quick connector SM 040 808 S
can be optionally provided (dia 8 by dia 8). Please include this option including the order code when ordering.
1.5. Winding insulation and heating
The motors are designed for operation on converters with intermediate circuit voltages up to 640 V.
Higher intermediate link voltages of
≤
800 V are possible, if voltage spikes on the motor terminals are limited to
<1200V by suitable filters in the motor supply line.