Three-phase synchronous motors DSC1-045-100
Technical alterations reserved
11/2016
DSC1-045-100
14
Baumüller Nürnberg GmbH
2.
Technical data
2.1. DSC1-045
3 AC 400 V mains voltage for converters with unregulated supply
Motor type
Nom.
speed
Stand-
still
torque
1)
Stand-
still
current
1
)
max.
static
torque
Max.
static
current
Rated
out-
put
1)
Rated
torque
1)
Rated
current
1)
Voltage
constant
Rated
fre-
quency
Rotor
inertia
(motor)
2)
Weight
3)
n
N
M
0
I
0
M
0.max
I
0.max
P
N
M
N
I
N
k
E/cold
f
N
J
m
min
-1
Nm
A
Nm
A
kW
Nm
A
V/
10001/min
Hz
kgcm
2
kg
DSC1-045K64U20-5
2000
2.7
1.3
8.7
4.9
0.5
2.5
1.3
140
166.7
1.4
4
DSC1-045S64U20-5
2000
4.5
2.0
18
8.9
0.9
4.1
1.9
154
166.7
2.3
5.5
DSC1-045M64U20-5
2000
6.2
2.6
26
12.7
1.1
5.4
2.3
162
166.7
3.2
7
DSC1-045K64U30-5
3000
2.7
1.9
8.7
7
0.7
2.3
1.6
98.5
250.0
1.4
4
DSC1-045S64U30-5
3000
4.5
2.7
18
12.4
1.1
3.5
2.3
111
250.0
2.3
5.5
DSC1-045M64U30-5
3000
6.2
3.7
26
18.2
1.3
4.2
2.6
113
250.0
3.2
7
DSC045K64U40-5
4000
2.7
2.4
8.7
8.9
0.8
1.9
1.8
76.9
333.3
1.4
4
DSC1-045S64U40-5
4000
4.5
3.5
17
15.9
1.1
2.7
2.3
86.3
333.3
2.3
5.5
DSC1-045M64U40-5
4000
6.2
4.7
26
23.3
1.0
2.5
2.1
88.4
333.3
3.2
7
1)
Coil overtemperature
∆ T < 105K; direct flange mounting (mounting plate 250 x 250 x 10 mm)
2)
Rotor inertia moment with PE brake: +1.0 kgcm²
3)
Weight with PE brake: +1.0 kg