TAM 00621
8
DSD 45-100
05/2007
Three-phase synchronous motor
English
2.4
Technical data
Designs (EN 60034-7)
IM B5 (IM V1, IM V3 )
Type of protection (EN 60034-5)
Motor housing
IP 65
Shaft exit
IP 64 (
with shaft sealing ring
IP 65 as an option)
Fan type of protection
IP 54
Terminal box
Only up to IP 65
Cooling method (EN 60034-6)
Standard:
IC 410
Completely enclosed motor design
Self-cooled,
no
fan
Optional:
IC 416 from shaft height 56
Completely enclosed motor
Surface-cooled,
with
fan
Air flow direction from motor NDE to DE
Electrical connections
(see
Appendix
)
Main connection
Standard:
8-pin connector:
Shaft height 45 to 56
Terminal box:
Shaft height 71 to 100
Optional:
Terminal box:
Shaft height 56
8-pin connector:
Shaft height 71 to 100
Control connection
Resolver:
12-pin connector
SinCos encoder:
12/17-pin
Brake (as an option)
Main connection
Thermal sensor
Resolver:
Control connection
SinCos encoder:
Main connection
Thermal motor protection (EN60034-11)
Thermal sensor KTY84 in stator winding
Winding insulation (EN 60034-1)
Thermal class F
Ambient temperature
0°C... +40°C
Altitude (EN 60034-1)
≤
1000 m above sea level
Intermediate storage
-30°C…+60°C (+85°C, see
Section 2.5
)
Bearings Rolling-contact
bearings with grease lubrication
Calculated bearing life
20,000h (approximate value)
Vibration severity (EN 60034-14)
Class A (previously N)
Vibration-resistant (EN 60068-2-6)
Radial 3g (10 Hz to 100 Hz)
Axial 0.5g (10 Hz to 100 Hz)
Holding brake
Option
Actual speed encoder
Standard:
2-pole
resolver
(High-quality version on request)
Optional:
SinCos
encoder
For additional technical data, please refer to technical product list DSD 45-100, which is available
from our website:
www.baumueller.de/e_index.htm
- Download- Technical documentations
Please request the relevant documentation if necessary.