Installation
Operation Manual
Safety I/O Terminals
SI4000 / SO4000
Document no.: 5.08009.05
Baumüller Nürnberg GmbH
46
7.1
7.1.6.1 Tested devices
The following list contains devices that were tested together with the SO4000 terminal.
The results only apply for the current device hardware version at the time of testing. The
tests were carried out in a laboratory environment. Modifications of these products cannot
be considered here. If you are unsure please test the hardware together with the safety
terminal.
Manufacturer
Type
Comment
Beckhoff
AX5801
TwinSAFE Drive option card: safe restart lock
Beckhoff
AX2000 AS option
Safe restart lock
Beckhoff
KL2964
Three-channel contact extension with feedback
Siemens
SIRIUS series S00
3RT1016-1BB42
Contactor
Telemecanique LP1K09
Contactor
Dold
LG5929.54/100
Extension module with floating contacts
The tests were carried out as function tests only. The information provided in the respec-
tive manufaturer documentation remains valid.
NOTICE!
Recommended protective circuits
We recommend R/C or diode-based protective circuits for these devices. Varistor-
based protective circuits should not be used.
5’
2
Output 2+
6’
Output 2-
7’
4
Output 4+
8’
Output 4-
NOTICE!
Test pulses
When selecting actuators please ensure that the SO4000 test pulses do not lead to
actuator switching or diagnostic message from the SO4000.
The test pulses of the SO4000 terminal outputs are not configurable and cannot be
switched off.