Product information
Syscompact 2000 M pro
20 / 98
822-175-2
3.2.1 System control panel
No. Element
Function
1
On/Off switch
Is used to switch on and off the system’s power supply
2
Status LEDs
Displays the operational earth monitoring status:
Green: The operational earthing is connected correctly. The resistance
between operational and protective earthing is < 4 ohm.
Red: There is a problem with the operational earthing. The resistance
between operational and protective earthing is > 4 ohm.
When the LED is illuminated red, the system cannot be operated. Further
information: Chapter
Fault indication with status LEDs
(on page 87)
Displays the surge protective device status:
Green: The surge protective device is working and protecting the system
from overvoltage.
Red: The surge protective device is damaged.
When the LED is illuminated red, the system cannot be operated.
3
key
Moves the system to the
Ready to switch on
operating state.
4
key
Moves the system to the
In operation
operating state.
5
key
Switches off the high voltage and moves the system to the
Ready for operation
operating state:
All test voltage supplies are switched off.
The internal capacitor and the test object are discharged.
6
Display with keys
Is used to select the methods and set the various parameters
The lowest line of the display shows the function of the associated key.
7
HV adjustment keys
(
/
)
Are used to increase or decrease the output voltage
8
Indicator lights
Indicate the system operating state:
Green:
Ready for operation
Red (flashing):
Ready to switch on
Red:
In operation
Summary of Contents for Sys compact 2000 M pro
Page 97: ......