Maintenance and care
Syscompact 2000 M pro
80 / 98
822-175-2
15.2 Maintenance schedule
Interval
Task
After each use
Check and clean the connection cables and the connection
accessories.
Further information: Chapter
Checking and cleaning the connection
cables and accessories
(on page 83)
Monthly
Check the condition of all connection cables.
Further information: Chapter
Checking and cleaning the connection
cables and accessories
(on page 83)
Every 12 months
(with frequent use, every 6 months
or as required)
Check the discharging resistance of the discharge unit.
Further information: Chapter
Testing the discharge unit
(on page 82)
Every 12 months
(with frequent use, every 6 months
or as required)
Check the ignition voltage of the spark gap.
Further information: Chapter
Checking the ignition voltage of the spark
gap
(on page 80)
As required depending on the
conditions of use
Clean the system components.
Further information: Chapter
Cleaning system components
(on page
As required
Replace the IRG 2000 rechargeable batteries.
Further information: Chapter
Replacing the rechargeable batteries of
the IRG 2000
(on page 85)
15.3 Checking the ignition voltage of the spark gap
Check the ignition voltage of the spark gap every 12 months or as required. The ignition
voltage must be between 500 and 1000 volts.
Procedure
Summary of Contents for Sys compact 2000 M pro