Maintenance and care
Syscompact 2000 M pro
84 / 98
822-175-2
15.6 Cleaning system components
WARNING
Residual voltage in connection fittings and in the live system
components
Danger to life, risk of injury due to electric shock.
You may touch the connection fittings that were under voltage only
after they have been discharged and earthed.
NOTICE
Damage to the device may be caused by using the wrong cleaning agents
Do not use any abrasive, corrosive cleaning agents or strong solvents.
Ensure material compatibility.
Do not clean the product with acetone or thinner.
Never clean electrical devices with water.
Prerequisites
Live plant parts located close by are covered.
The system is switched off and is disconnected from the supply voltage. Further
information: Chapter
Safety instructions for maintenance work
(on page 79)
1. If required, clean the device surfaces with mild detergent and a lint-free cloth.
NOTICE!
Damage to the device due to leaking fluids.
2. Do not allow liquids to leak into the devices.
Summary of Contents for Sys compact 2000 M pro