Maintenance and care
Syscompact 2000 M pro
86 / 98
822-175-2
15.8 Checking and replacing the fuse in the TDR connection cable
(IRG 2000)
Prerequisites
Multimeter
Fuse: F 1 A, 50 kA, 500 V
Procedure
1. Unscrew one of the terminals of the TDR connection cable.
2. Remove the fuse from the fuse holder.
3. Check if the fuse is working. For this, perform a continuity check with a multimeter.
4. If the fuse is not working, replace the fuse.
5. Screw the terminal back onto the TDR connection cable.
6. Check the fuse on the second terminal of the TDR connection cable.
15.9 Regular calibration
It is important to calibrate the system regularly to ensure that the technical data given in this
user manual are guaranteed. We recommend calibrating it once a year. The calibration may
only be carried out by personnel trained and authorised by BAUR.
For information on calibration, contact your nearest BAUR representative
(http://www.baur.eu/baur-worldwide).