Installation

 

 

1.

 

Verify that the opening dimensions are correct. 
 

2.

 

Install the mounting flanges onto the pre-drilled holes in the outer edges of the inside 
face by installing the flanges so the face with the slots is against the inside face of the 
drawer assembly and the edge the slot is closest to is at the top of the flange, (See Fig. 1). 
 Leave the screws slightly loose until the wall anchors are installed. 
 

3.

 

Lay a bead, or two, of caulk along the bottom of the opening and up each side an inch or 
two in a position so that the bead will be about an inch or two back from the outside face 
of the drawer assembly. 
 

4.

 

Position the drawer assembly into the opening and level. 
 

5.

 

Anchor the mounting flanges to both sides of the wall opening, then tighten the flanges to 
the inside face. 
 

6.

 

Caulk the outside perimeter to make weather tight. 
 

7.

 

Test Drawer operation. 

 

 

 

Installation with the Window Installed, (Drawer Retrofit)

 

 

1.

 

Verify that the opening dimensions are correct. 
 

2.

 

Remove the inside Back Panel, (See Fig. 2). 
 

3.

 

Remove the (4) screws that hold the Counter Top to the drawer assembly. 
 

4.

 

Slide the Counter Top and Red Bin Assembly out of the drawer shell/frame through the 
Back Panel opening. 
 

5.

 

Install the mounting flanges onto the pre-drilled holes in the outer edges of the inside 
face by installing the flanges so the face with the slots is against the inside face of the 
drawer assembly and the edge the slot is closest to is at the top of the flange, (See Fig. 1). 
 Leave the screws slightly loose until the wall anchors are installed. 
 

6.

 

Lay a bead, or two, of caulk along the bottom of the opening and up each side an inch or 
two in a position so that the bead will be about an inch or two back from the outside face 
of the drawer assembly. 
 

7.

 

Position the drawer assembly into the opening and level. 
 

8.

 

Anchor the mounting flanges to both sides of the wall opening, then tighten the flanges to 
the inside face. 

Summary of Contents for Basic Manual Transaction Drawer 3

Page 1: ...Road Maineville Ohio 45039 513 677 0500 Basic Manual Transaction Drawer 3TM BD3TM BD3 1 TM Installation and Service Manual Copyright 2016 E F Bavis Associates Inc Revised 05 31 2016 All Right Reserved...

Page 2: ......

Page 3: ...llation 2 Service Information 3 Troubleshooting 3 Fig 1 Mounting Flange Assembly 4 Fig 2 Removing Back Panel Illustration 5 Exploded Parts Diagram 6 9 Parts List 10 Basic Drawer 3 BD3 Dimensions 11 Ba...

Page 4: ......

Page 5: ...not to approach when the drawer is open Full 14 extension of drawer No wiper or sliding type weather seals Our seals are replaceable and operate in compression to reduce wear and provide the best pos...

Page 6: ...ght 7 Test Drawer operation Installation with the Window Installed Drawer Retrofit 1 Verify that the opening dimensions are correct 2 Remove the inside Back Panel See Fig 2 3 Remove the 4 screws that...

Page 7: ...rocedure to reinstall the back panel Drawer Bin Removal To remove the Red Bin it is necessary to remove the back panel as stated above and then remove the two bolts and spacers attaching the operator...

Page 8: ...4 Fig 1 Mounting Flange Assembly...

Page 9: ...5 Fig 2 Removing Back Panel...

Page 10: ...6 Inside Parts Exploded View...

Page 11: ...7 Red Bin Assembly Exploded View...

Page 12: ...8 Customer Door Exploded View...

Page 13: ...9 Audio Components Exploded View...

Page 14: ...1 4 Flat Washer 2 21 95005002 1 4 20 Nylon Locking Nut 8 22 28013592 BD2 Customer Door Assembly 23 1 23 28020021 BD2 Customer Door Gasket 1 24 92005002 6 32 Nylon Locking Nut 2 25 28017021 BD Right Cu...

Page 15: ...OR DRAWER MINIMUM WALL OPENING 28 3 4 WIDE X 10 1 8 TALL MAXIMUM WALL OPENING 30 1 2 WIDE X 13 1 2 TALL IF THE SITE DIMENSIONS EXCEED THE RANGE OF ANY OF THE DIMENSIONS LISTED CONTACT THE FACTORY WHIL...

Page 16: ...FOR DRAWER MINIMUM WALL OPENING 28 3 4 WIDE X 10 1 8 TALL MAXIMUM WALL OPENING 30 1 2 WIDE X 11 3 4 TALL IF THE SITE DIMENSIONS EXCEED THE RANGE OF ANY OF THE DIMENSIONS LISTED CONTACT THE FACTORY WH...

Page 17: ...tance from the drive surface to the bottom of the moving bin is 32 to 40 Actual distance is to be determined by others Dimensions shown are for reference only BD3 shown 36 5 8 35 13 16 6 29 13 16 40 D...

Page 18: ......

Reviews: