Page 30
Alarm Displays In Play Mode
Regardless of the mode selected, Monitor-B will always display live images. Hence,
during PLAY mode, live alarm inputs will cause live alarm displays on Monitor-B, not
Monitor-A. Monitor-A will continue to display playback images.
Monitor-A During PLAY Mode - Recorded Alarms
In PLAY mode, the Monitor-A display will not automatically provide alarm displays
based on recorded alarm status. Monitor-A will display the playback images from the
VCR according to your selected formats, and will display the normal “A” alarm
indicator only if a camera was in alarm at the time that a recording was made.
CAUTION: If a camera which had an alarm at the time of recording is not selected
by you for display, there will be no on-screen indication that the alarm occurred. Thus
if you are looking for cameras in alarm during playback, ensure that all the cameras
on tape are displayed by using a 10-way multi-screen.
Monitor-B During PLAY Mode
Monitor-B will continue to display live images, according to your selection. If a live
alarm occurs during play mode, then Monitor-B will automatically switch to the
camera in alarm. It will sequence at a 1 second dwell time for multiple cameras in
alarm. After you have cancelled the alarm, Monitor-B will continue to display the
alarm camera which was on the screen at the time that the alarm was cancelled, or
will continue to sequence if sequencing was enabled.
Alarm LED And Internal Buzzer In PLAY Mode
The LED and internal buzzer alarm indicators will be activated only if a live alarm is
active. Alarm status played back from a recorded tape has no effect on these
indicators. The internal buzzer can be disabled via an internal hardware strap.
Alarm Displays In Record Mode, Simplex Models Only
During RECORD mode only, Monitor-A displays are always analogue full-screen,
and is the same as Monitor-B’s normal mode.
As a result, the simplex model cannot display a multi-screen image on Monitor-A
during recording, and alarms cannot be manually frozen. If an alarm occurs during
RECORD mode, Monitor-A will automatically switch to the live analogue full-screen
display of the camera in alarm. If multiple alarms are active while recording, the
simplex unit will automatically sequence between the alarm cameras at a fixed one
second dwell.
Summary of Contents for ZMX/BD/10
Page 1: ...HBZMXSIB 10 16SD OP 1 Page 1 Operating Instructions ZMX BD 10 ZMX BS 10 ZMX CS 10 Multiplexers...
Page 3: ...HBZMXSIB 10 16SD PR 1 Page 2 This page is intentionally blank...
Page 5: ...HBZMXSIB 10 16SD PR 1 Page 4 This page is intentionally left blank...
Page 7: ...HBZMXSIB 10 16SD PR 1 Page 6 This page is intentionally left blank...
Page 78: ...HBZMXSIB 10 16SD OP 1 Page 2 This page is intentionally blank...
Page 80: ...HBZMXSIB 10 16SD OP 1 Page 4 This page is intentionally blank...