HBZMXSIB/10/16SD-PR-1
Page 74
buffer[1] = 0xAA;
buffer[2] = number of bytes starting from buffer[4];
buffer[3] = MACRO1 to MACRO16;
buffer[4] - buffer[x] The macro sequence keys
The numerical values of the keys are as follows:
Record
= 1
Play
= 2
Live
= 3
Alarm
= 4
Freeze
= 5
Zoom
= 6
Sequence
= 7
Multiscreen
= 8
’1’
= 9
’2’
= 10
’3’
= 11
’4’
= 12
’5’
= 13
’6’
= 14
’7’
= 15
’8’
= 16
’9’
= 17
’10’
= 18
’11’ = 19
’12’
= 20
’13’
= 21
’14’ = 22
’15’ = 23
’16’ = 24
Setup = 25
Select
= 26
RESERVED
= 27
RESERVED
= 28
Macro Special 1 = 29 /* Activate Alarm Output 1*/
Macro Special 2 = 30 /* Reset Alarm Output 1 */
Macro Special 3 = 31 /* Pause Macro for 1 second
*/
Macro Special 4 = 32 /* Pause Macro for 5 seconds
*/
RESERVED
= 33
Mon_B Key
= 34
Camera Power Key = 35
Wash Key = 36
Auto Pan Key = 37
Lights Key
= 38
Wipe Key
= 39
Preset Key
= 40
Focus Far Key = 41
Focus Near Key
= 42
Iris Close Key = 43
Iris Open Key = 44
Zoom In Key = 45
Zoom Out Key = 46
Telemetry_Key = 47
Left Arrow Key = 48
Right Arrow Key = 49
Up Arrow Key = 50
Down Arrow Key
= 51
Up Left Key
= 52
Down Left Key = 53
Up Right Key = 54
Down Right Key = 55
Macro Special 5 = 56 /* Activate Alarm Output 2 */
Macro Special 6 = 57 /* Reset Alarm Output 2 */
The last byte of the macro buffer[x] = 58; Macro_End
The number of bytes in the macro may not exceed 32.
y) Enable activity detection
buffer[0] = 0xff;
buffer[1] = 0xAA;
buffer[2] = 16;
buffer[3] = ENACTIVITY;
buffer[4] - buffer[19] = BINARY list of 16 numbers -
digits (0 - disable, 1 -enable)
z) Request activity settings
buffer[0] = 0xff;
buffer[1] = 0xBB;
buffer[2] = 0;
buffer[3] = UP_ACT_SETTINGS;
aa) Request activity grid
buffer[0] = 0xff;
buffer[1] = 0xBB;
buffer[2] = 0;
buffer[3] = UP_ACT_GRID;
ab) Request alarm and videoloss status
buffer[0] = 0xff;
buffer[1] = 0xBB;
buffer[2] = 0;
buffer[3] = UP_ALM_AND_VDL;
ac) Download activity grid
buffer[0] = 0xff;
buffer[1] = 0xAA;
buffer[2] = 32;
buffer[3] = DN_ACT_GRID_1 to DN_ACT_GRID_16;
buffer[4] - buffer[35] BINARY digits corresponding to
zones.
Two bytes per row, 16 rows. (1 - active, 0 -
off)
NOTE: This message must be used with caution.
Delays of 100ms must be inserted between
consecutive camera grids.
ad) Downloading Timed Macro Information
buffer[0] = 0xff;
buffer[1] = 0xAA;
buffer[2] = 6;
buffer[3] = DN_TIMED_MACRO;
buffer[4] = Event number (1 - 20)
buffer[5] = Day (0 - 8) 0 -> Disabled
buffer[6] = Hour (1 - 12)
buffer[7] = Minute (0 - 59)
buffer[8] = AM/PM (0 - AM, 1 - PM)
buffer[9] = Macro Number (1-16)
ae) Setting the Record Lock
buffer[0] = 0xff;
buffer[1] = 0xAA;
buffer[2] = 1;
buffer[3] = REC_LOCK;
buffer[4] = 0 - OFF, 1 - ON
af) Setting the VCR Type
buffer[0] = 0xff;
buffer[1] = 0xAA;
buffer[2] = 1;
buffer[3] = VCR_TYPE;
buffer[4] = 0 - Type A,1 - Type B
ag) Setting the Vext Pulse active edge
buffer[0] = 0xff;
buffer[1] = 0xAA;
buffer[2] = 1;
buffer[3] = SWITCH_EDGE;
Summary of Contents for ZMX/BD/10
Page 1: ...HBZMXSIB 10 16SD OP 1 Page 1 Operating Instructions ZMX BD 10 ZMX BS 10 ZMX CS 10 Multiplexers...
Page 3: ...HBZMXSIB 10 16SD PR 1 Page 2 This page is intentionally blank...
Page 5: ...HBZMXSIB 10 16SD PR 1 Page 4 This page is intentionally left blank...
Page 7: ...HBZMXSIB 10 16SD PR 1 Page 6 This page is intentionally left blank...
Page 78: ...HBZMXSIB 10 16SD OP 1 Page 2 This page is intentionally blank...
Page 80: ...HBZMXSIB 10 16SD OP 1 Page 4 This page is intentionally blank...