Page 9

Installation Instructions

ZMX+EXP32

CONNECTIONS

Power

The ZMX+EXP32 is supplied with a 12V DC class 2 output, auto-ranging: 110/230V AC (+6%, -10%)  50Hz,

external power supply. 

Do not use any other power supply

. Do not connect the power until you have read the

section, 

Powering Up your ZMX+EXP32

 below.

Attach a suitable 3 pin plug following the wiring instructions on the label attached to the mains lead.

Note: The manufacturer accepts no responsibility for any damage caused by the use of any other power supply.

Plug the mini power connector from the 12V DC power supply into the socket marked 12V DC on the rear of your

expander unit. Adjacent to the socket is a cable anchor. Use a small cable tie to attach the power supply cord to

the cable anchor. This helps to prevent inadvertent power disconnection which may be caused by the power

cable being pulled.

Expander cable

The expander unit and multiplexer are connected together by means of a special cable. Attach the cable and

ensure the connector screws are tightened to prevent the cable being pulled out
.

POWERING UP YOUR ZMX+EXP32

Your expander unit must be powered up before the multiplexer. This is because the multiplexer polls the expander

unit as part of its power-up sequence. After all the relevant connections have been made between the expander

unit and multiplexer, perform the following sequence:
1. Disconnect the power from your multiplexer.
2. Connect the power to your expander unit
3. Reconnect the power to your multiplexer

SETTING THE MULITPLEXER TO 32 WAY

Your multiplexer must be set to 32 way in order to gain access to various menu items for the expander unit. This

is done as follows:
1. Enter the menu system of your ZMX+CT16M4 multiplexer.
2. Use the left/right arrow keys to select 

Main

.

3. Use the up/down arrow keys to select 

Camera Setup

 and press the enter key.

4. Use the up/dwon arrow keys to select 

Camera Selection 16/32

 and press enter.

5. In the 

Number of Cameras

 field, use the left/right arrow keys to select 

32.

6. Use the up/down arrow keys to select 

OK 

and press enter.

NOTE: After selecting OK, the multiplexer will reset itself. Any parameters that were previously set up in

the multiplexer will be lost. The multiplexer must be powered down and back on again in order for the

new settings to take effect.

Summary of Contents for ZMX plus ZMX+EXP32

Page 1: ...Please read this manual before operating your multiplexer...

Page 2: ...nstallation Instructions IMPORTANT The first few pages of these instructions contain important information on safety and product conformity Please read and ensure that you understand this information...

Page 3: ...Electromagnetic Compatibility EMC 5 Manufacturer s Declaration of Conformance 5 Unpacking 6 Associated Equipment 6 Location 6 Ventilation 6 Temperature 6 Overview 7 Connections 8 Camera Inputs 8 Monit...

Page 4: ...aving a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician Do not def...

Page 5: ...he casing has been damaged If the unit exhibits a distinct change in performance If the unit has no power even when the power supply appears to operate correctly If this is the case then ask a service...

Page 6: ...ur multiplexer and expander unit which permits secure isolation in accordance with your national wiring regulations your expander unit has no ON OFF switch for security reasons LOCATION Ensure that th...

Page 7: ...s Fig 1 Rear Panel Layout The rear panel of your expander unit has the following connections 16 loop through camera inputs with automatic termination Three analogue monitor outputs C D and E Monitor c...

Page 8: ...he 32 way expander unit is used Monitors C D and E attach directly to the BNC connectors provided on the expander unit and not the multiplexer This is to ensure that the monitor signals are correctly...

Page 9: ...being pulled out POWERING UP YOUR ZMX EXP32 Your expander unit must be powered up before the multiplexer This is because the multiplexer polls the expander unit as part of its power up sequence After...

Page 10: ...anging 110 230V AC 10 50Hz to 12V DC external power supply provided Power Consumption Max 10W Physical Specifications Operational temperature limits 0O C to 40O C at 10 to 80 relative humidity non con...

Page 11: ...Page 11 Installation Instructions ZMX EXP32...

Page 12: ...dbury Park Industrial Estate Stockport SK6 2SU England Tel 0161 406 6611 Fax 0161 406 7677 Visit our Web site http www baxall com Baxall Security Ltd reserve the right to make changes to the product a...

Reviews: