with four no. 10 x 2in. woodscrews.
6.3 Gas supply connection.
8mm rigid tubing must be used to connect the gas supply to the appliance. An olive and
nut are provided for connection to the inlet “T” connector on the appliance. The
connector can be rotated to allow connection from either side or the rear. The connector
includes a valve for isolating the gas supply.
The closure plate has a cut-out for rear connection.
Seal the gap between the cut-out and the supply
pipe.
Pressure check the installation pipework for gas
soundness. In the United Kingdom check in
accordance with the current edition of BS6891. In
the Republic of Ireland refer to the current edition of
IS 813 “Domestic gas installations”.
6.4 Fit the ceramic fuel effect and window.
6.4.1
Place the ceramic fuel effect in position Make
sure that it rests on the ledges at the sides of the
firebox and that its back face is touching the
horizontal rib at the back of the firebox (See figure
12).
6.4.2
Replace the window unit. Secure the window
unit to the firebox the two screws removed
previously.
7 CONTROL AND PRESSURE CHECKS
7.1 Check control settings.
7.1.1
If closed, open the isolating valve at the inlet ‘T’ connector.
7.1.2
To help in checking the control positions while the fascia is detached, place the
control bezel over the gas tap spindle and against the tap bracket. Temporarily secure to
the tap bracket with one of the screws.
7.1.3
Fit the control knob over the gas tap spindle.
7.1.4
Depress the control knob and turn anticlockwise partially towards the 1/IGN
position until some resistance is felt. Keep depressed at this position to purge air from
the system then, while keeping it depressed, turn fully to the 1/IGN position. A spark
should be generated at the pilot while turning. The spark should ignite the pilot.
7.1.5
When pilot ignition has been achieved, keep the control knob depressed for
approximately ten seconds to allow the thermocouple probe to warm up and then release
it. If the pilot does not remain alight, ensure that the air has been purged, that the pilot
Page 19
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 12. Ceramic fuel
effect location