4.12
Propane gas appliances must not be installed in a room that is built entirely below
ground level (see BS 5871 Part 3).
4.13
If the appliance is to be fitted
against a wall with combustible cladding,
the cladding must be removed from the
area shown in figure 3
4.14
Combustible side projections up to
75mm forward of the fixing plane of the
fire are to be a minimum of 125mm from
the fireplace opening (See figure 4)
4.14.1
Combustible side projections
greater than 75mm forward of the fixing
plane of the fire are to be a minimum of
178mm from the fireplace opening (See
figure 4).
Page 12
INSTALLER GUIDE
Firefront
Dimension 'X' (mm)
Dimension 'Y' (mm)
Azure
400
65
Quattro / Anthem
390
65
Majestic
400
50
Figure 4. Appliance dimensions