10.
Remove the gas valve
11.
Refit in the reverse order.
11.5 To remove the piezo
generator.
1.
Remove the gas valve as in
section 11.4.
2.
Make sure that the tap is in the
off position.
3.
Remove the circlip holding the
piezo unit to the tap. Remove the
piezo unit.
4.
Replace in the reverse order.
11.6 To grease the control tap.
1.
Detach the tap and remove the
piezo generator as section 11.5 making sure that the tap is in the off position.
2.
Remove the two screws from the head of the tap. Remove the niting head and
spindle complete with collar and spring.
3.
Note the position of the slot in the plug-mark its position on the tap body.
4.
Remove the plug rotating slightly while pulling.
5.
Clean and grease the plug lightly with suitable grease. Do not apply excessive
grease. Particularly, make sure that the gas ports in the tap are not restricted by grease.
6.
Push the plug into the tap body and position the slot in line with the mark previously
made on the tap body.
7.
Reassemble the niting head and spindle complete with collar and spring making sure
that the components are correctly engaged. Check the operation of the tap.
8.
Refit the piezo generator.
11.7 To replace the burner.
(See figure 21).
1.
Remove the burner unit (See section 11.2).
2.
Support the elbow injector and unscrew the
injector nut.
3.
Remove the two screws from the burner
clamping plate (See figure 21)
4.
Lift the right hand side of the burner, slide it to
the right and lift clear
5.
Refit in reverse order.
Page 24
INSTALLER GUIDE
Figure 21. Removal of burner
Figure 20. Gas valve (Viewed from rear
with burner turned over)