8.
This appliance is supplied with a rear ceramic
support bracket. Fit this using two screws
supplied (See figure 15)
9.
This appliance is supplied with a flue
restrictor for use where the flue draught is
excessive. The restrictor must NOT be fitted
where a precast flue or a flue liner is used. For
all other installations the restrictor should be
fitted. There may however, be certain
exceptional circumstances where fitting the
restrictor causes the fire to fail the spillage test.
In such cases the restrictor
will have to be removed.
After removal conduct the
spillage check again.
10.
The restrictor is packed
loose with the appliance
and is fixed with three
screws (See figure 16).
11.
There is a length of self
adhesive foam seal supplied
with the fire. This will need
to be fitted to the outer rear
edges of the side and top
flanges of the convection box. Cut a 485mm
length of foam seal. Be careful not to stretch the
seal when measuring. Remove the protective
backing from the foam seal and fit this to the rear
of the top flange (See figure 17). Cut two 580mm
lengths. Fit these to the rear outer edges of the
side flanges. Ensure that there is no gap between
the foam seals where they meet at the top flange
(See figure 17)
(Visage, Decadent, Obsession and Eternal
models only)
12.
Fit the two surround securing brackets to the
convection box side flanges with the screws
supplied. Note the different orientation of the
brackets at left and right sides (See figure 18)