3.
Loosen the thermocouple nut to free the microswitch leads and pull the leads clear of
the thermocouple interrupter block (See figure
49).
4.
Detach the bridging bracket, microswitch
assembly by removing two screws (See figure
48).
5.
Replace in the reverse order. When refitting
the leads to the interrupter block, make sure that
they are secured firmly to give a good electrical
contact.
17.4 To remove the fascia.
1.
Remove the bottom front cover and the fire
front casting.
2.
Detach the control-linking bar from the
control pivot bracket by removing the knurled screw,
which joins the control linking bar to the control pivot
unit (See figure 50).
3.
Remove the two screws securing the bottom of the
fascia to the sides of the convection box (See figure
51).
Page 41
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 51. Fascia bottom
location (Shown with Visage
fascia).
Figure 50. Control linkage
disconnection
Figure 49. Thermocouple interrupter
block