55).
5.
Replace in the reverse order.
17.8 To remove the electronic ignition
generator.
1.
Remove the bottom front and fire front
castings. For ‘Adorn’ and ‘Icon’ models
remove the fascia (See section 17.4).
2.
Remove the ceramic fuel effect.
3.
Remove the battery.
4.
Remove the spark lead.
5.
Unscrew the four support bracket screws (See
figure 56). The generator and its support bracket
can now be moved forward. Be careful not to
apply tension to the microswitch leads.
6.
Remove the two fixing screws that attach the
generator unit to the support bracket. The igniter
generator can now be removed (See figure 56)
7.
Remove the two leads to the switch and
remove the spark lead. If necessary, mark them to
ensure that they are replaced on to the correct
terminals.
8.
Replace the generator
9.
Refit in the reverse order.
17.9 To remove the thermocouple interrupter
block.
(See figure 49).
1.
Remove the burner unit (See section 17.7).
2.
Detach the thermocouple from the interrupter
block by unscrewing the thermocouple nut.
3.
Detach the two microswitch leads from the interrupter
block.
4.
Remove the interrupter block by unscrewing from the
gas shut-off tap.
5.
Refit in the reverse order. If the microswitch leads
cannot be easily attached to the interrupter block when it
is fully tightened to the gas shut-off tap, slacken it and
rotate to allow the leads to be fitted. Retighten making
sure that the leads remain in place in the interrupter
block. Fit and tighten the thermocouple nut making sure
Page 44
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 57. Pilot unit removal
Figure 56. Removal of
electronic generator
Figure 55. Burner attachment points