2. APPLIANCE DATA
*
When converted using kit 0595211.
The appliance data label is located on a plate at the base of the fire. This can be seen by
lowering the bottom front cover of the fascia.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and the
result is as below :
Model
Efficiency % (Gross)
740
58
740 when converted to LPG.
61
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica Certification
services (0087). The efficiency value may be used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings.
The convertion of
net
efficiency to
gross
was achieved by multiplying the net efficiency
by the following conversion factor from Table E3 of SAP 2005, rounding down to the
nearest whole number.
Page 6
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Gas
Natural (G20)
Propane (G31) *
Inlet Pressure
20mbar
37mbar
Input - Max. (Gross)
6.85kW (23,400 Btu/h)
6.7kW (22,860 Btu/h)
Input - Min. (Gross)
2.7kW (9,410 Btu/h)
4.3kW (14,670 Btu/h)
Inlet Test Pressure (Cold)
20.0 ± 1.0mbar (8.0 ± 0.4in
w.g.)
37.0 ± 1.0 mbar (14.85 ±
0.4in w.g.)
Gas Connection
8mm pipe
8mm pipe
Burner Injector
Stereomatic Cat 82 - 074
Stereomatic Size 132
Pilot & Atmosphere Sensing
Device
Copreci Ref. O.D.S
21500/166
Copreci Ref. O.D.S
21500/166 Fitted with RBM
180 -02 injector
Ignition
Electronic
(Battery 9V PP3)
Electronic
(Battery 9V PP3)
Aeration
See section 17.1
Non-adjustable