This product uses fuel effect pieces and burner compartment walls containing
Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres.
Excessive exposure to these materials may cause irritation to eyes, skin and
respiratory tract. Consequently, it is important to take care when handling these
articles to ensure that the release of dust is kept to a minimum. To ensure that the
release of fibres from these RCF articles is kept to a minimum, during installation
and servicing we recommend that you use a HEPA filtered vacuum to remove any
dust and soot accumulated in and around the fire before and after working on the
fire. When replacing these articles we recommend that the replaced items are not
broken up, but are sealed within a heavy duty polythene bag, clearly labelled as
RCF waste. RCF waste is classed as a stable, non-reactive hazardous waste and
may be disposed at a landfill licenced to accept such waste. Protective clothing is
not required when handling these articles, but we recommend the use of suitable
gloves to prevent irritation. We also recommend you follow the normal hygiene
rules of not smoking, eating or drinking in the work area and always wash your
hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos or
asbestos related products.
3. GENERAL INSTALLATION REQUIREMENTS
3.1
The installation must be in accordance with these instructions.
For the user’s protection, in the United Kingdom it is the law that all gas appliances are
installed by competent persons in accordance with the current edition of the Gas Safety
(Installation and Use) Regulations. Failure to install the appliance correctly could lead
to prosecution. The Council for the Registration of Gas Installers (CORGI) requires its
members to work to recognised standards.
In the United Kingdom the installation must also be in accordance with:
All the relevant parts of local regulations.
All relevant codes of practice.
The relevant parts of the current editions of the following British Standards:-
BS EN 1856 Part 1 which replaces BS 715
BS EN 1858 which replaces BS 1289 Part 1
BS EN 1806 which replaces BS 1289 Part 2
BS EN 1856 Part 1 which replaces BS 4543 Part 2
BS 5440 Part 1
Page 7
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Gas
Conversion factor from
net
to
gross
efficiency
Natural Gas
0.901
LPG
0.921