10.4 Lighting the pilot.
Please note:- The fire must be lit manually.
1.
Ensure that the pilot burner
control knob is in the OFF
position (1 in figure 23).
2.
Depress the pilot burner
control knob and turn anti-
clockwise to the ignition
position (2 in figure 23) to
activate the piezo ignition
system. A 'click' will be heard
and the pilot should light. If
the pilot does not light
immediately, repeat the above
procedure, keeping the knob
depressed for several seconds
in order to purge any air from
the system.
If after ten seconds, ignition has not occurred, turn the control knob back to the OFF
position. Wait 30 seconds and then repeat the ignition procedure.
3.
When the pilot is alight keep the knob depressed for ten seconds to allow the pilot
flame to stabilise.
4.
Release the knob. When the knob is released, the pilot should remain alight. If the
pilot fails to remain alight, repeat the ignition procedure, this time keeping the knob
depressed for a longer period of time.
10.5 Checking the heat settings.
1.
Once the pilot light is established, light the main burner by turning the pilot burner
control knob anti-clockwise to the "main burner on" position (3 in figure 23), and by
then turning the main burner control knob to the high position (5 in figure 23).
2. Check the full range of heat settings by turning the main burner control knob slowly
between the high position and the low position (4 in figure 23).
10.6 To turn the fire back to pilot setting.
Turn the main burner control knob fully clockwise. Alternatively turn the pilot burner
control knob clockwise to the ignition position (2). Refer to figure 23.
10.7 To turn the fire off.
Rotate the pilot/burner control knob clockwise to position 1, as shown in figure 23.
Page 26
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2006.
Figure 23. Appliance manual controls.