SAFETY
Do
have the fire installed by a competent person. In the United Kingdom, installation
must be in accordance with the latest edition of the Gas Safety (installation & use)
Regulations. In the Republic of Ireland, installation must be in accordance with all
national and local regulations in force.
Do
have the chimney swept prior to installation if it was previously used for solid fuel.
Do
have the fire installed in accordance with the installation instructions.
Do
provide a minimum clearance of 700mm from the base of the firplace opening to
any shelf made of wood or other combustible material where the shelf is not more than
150mm deep. For a shelf deeper than 150mm, add 12.5mm to the clearance for every
25mm of additional shelf depth (See graph1).
Do
wait three minutes before attempting to relight if the fire is switched off or the
flames are extinguished for any reason. (Your fire is fitted with a safety device that will
Page 5
OWNER GUIDE
©
Baxi Heating U.K. Limited 2006.
Graph 1. Combustible shelf clearances
IF YOU SMELL GAS
!
DON’T SMOKE.
!
EXTINGUISH ALL NAKED FLAMES.
!
DON’T TURN ELECTRICAL SWITCHES ON OR OFF.
!
TURN OFF THE GAS SUPPLY AT THE METER.
!
OPEN DOORS AND WINDOWS TO GET RID OF THE GAS.
!
IMMEDIATELY CALL THE GAS EMERGENCY SERVICE FROM A
NEIGHBOURS PHONE - SEE YOUR LOCAL TELEPHONE DIRECTORY.