15.3 To remove the spillage plate.
1.
Remove the fascia as in section 15.1.
2.
Detach the spillage plate from the hotbox by
removing the four screws (See figure 29).
3.
Replace in the reverse order.
15.4 To remove the inner panel.
1.
Remove the fascia as in section 15.1.
2.
Remove the burner as in section 15.2.
3.
Remove the spillage plate as in section 15.3.
4.
Remove the six screws from the side of the
inner panel (See figure 30).
5.
Carefully lift the inner panel and pull forward to
remove.
6.
Replace in the reverse order.
15.5 To remove the pilot unit.
1.
Remove the burner assembly (See section
15.2).
2.
If turning the burner upside down, ensure that
the work surface is suitably protected This will
avoid damage to the work surface. Detach the
pilot pipe from the pilot unit.
3.
Detach the thermocouple from the gas valve.
4.
Detach the electrode lead from the underside
of the electrode tab.
6.
Remove the two screws securing the pilot unit
(See figure 31).
7.
Refit in the reverse order.
Note:
1.
The pilot unit is an atmosphere
sensing device. It must be replaced as a
whole assembly. Its individual
components are not separately
replaceable.
Page 27
INSTALLER GUIDE
Figure 31. Pilot unit removal
Figure 30. Removal of inner panel
Figure 29. Spillage plate removal