background image

5.0 Care of the Boiler

8

© Baxi Heating UK Ltd 2007

5.1

Cleaning the Outer case

The painted panels should be wiped with a damp cloth and
then dried completely. 

DO NOT USE ABRASIVE

CLEANING AGENTS.

5.2

Protection & Precaution

1. The boiler incorporates an integral frost protection feature

that will operate in both modes. If the boiler temperature falls

below 5° C, then the boiler will operate until the water

temperature has been raised.

2. If a system frost thermostat has been fitted (your installer

will be able to advise you), then to operate correctly and

protect your system, the gas and electricity must be left on and

the appliance set in the central heating mode.

3. The boiler incorporates an integral pump protection feature

which continually monitors the time since the pump last

operated. To prevent seizure, the pump will operate for

approximately 1 minute if it has not run in the last 24 hours.

5.3

Fault Indication

1. If a fault occurs on the boiler an error code may be shown

on the facia display (Fig. 5).

2. The codes are either two or three digit, preceded by the

letter 'E'. For example, code E133 will be displayed by 'E1'

alternating with '33'. E50 is shown as 'E' then '50'.

3. E20, E28, E50, E125 & E160 indicate faulty components.

You should make a note of the displayed error code and

contact your installer or service engineer.

4. If E110 or E130 is displayed overheat of the primary water

or flue system has occurred. Turn the selector switch to the

reset position and hold for at least 5 seconds. If the boiler

does not relight, or the code is displayed regularly contact your

installer or service engineer.

5. E119 is displayed when the primary water pressure is less

than 0.5 bar. After repressurising the system the boiler should

operate. Your installer will be able to advise you about the

method of repressurising. See page 6 for further details. 

6. E133 indicates that the gas supply has been interrupted,

ignition has failed or the flame has not been detected. Ensure

that the gas supply has not been turned off, and turn the

selector switch to the reset position and hold for at least 5

seconds. If the boiler does not relight, or the code is displayed

regularly contact your installer or service engineer.

Central Heating NTC Fault

Flue NTC Fault

Hot Water NTC Fault 

Safety Thermostat Operated

Water Pressure Switch Not Operated

Circulation Fault (Primary Circuit)

Flue NTC Operated

Interruption Of Gas Supply or Flame Failure

Fan or Fan Wiring Fault

E20

E28

E50

E110

E119

E125

E130

E133

E160

Table of Error Codes

Reset

bar

0

1

2

3

4

Display

Then

Fig. 5

Summary of Contents for 24

Page 1: ...Baxi Heating UK Ltd 2007 User s Guide and Important Warranty Information Gold Combi 24 28 33 HE Please keep these instructions in a safe place If you move house please hand them over to the next occupier ...

Page 2: ...e proposed use to the following address The Company Secretary Baxi Heating UK Ltd Pentagon House Sir Frank Whittle Road Derby DE21 4XA Full acknowledgement of author and source must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Baxi Heating UK Ltd is a BS EN ISO 9001 Accredited Company Th...

Page 3: ...dicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water Boiler Output Temperature In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in degrees centigrade ...

Page 4: ... on Reset Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure needle in the GREEN section between 1 and 2 5 bar If the reading falls below 1 bar repressurise the system as described in section 3 1 Does the display show an error code e g E133 E110 Boiler not working NO NO YES YES YES ...

Page 5: ...fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible YES NO CONTACTYOUR INSTALLER OR SERVICE ENGINEER YES 12 1 2 3 4 5 6 7 8 9 1 0 11 CH ON CH OFF Typical examples of external timer NO ...

Page 6: ... pressure falls below 0 5 this may indicate a leak on the central heating system Fig 2 Error Code E119 will be shown on the display 3 2 To Re Pressurise the System 1 The procedure is for the optional filling loop kit when fitted However even if your boiler has an external loop the principle is similar 2 Look at the boiler from underneath There will be two taps at the end of copper pipes one with a...

Page 7: ...arning labels on your boiler 6 Your boiler should have the following minimum clearances for Safety and Maintenance Fig 34 Top 200mm Bottom 200mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing 7 If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings 8 Flammable materials must not be stored in...

Page 8: ...E20 E28 E50 E125 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 or E130 is displayed overheat of the primary water or flue system has occurred Turn the selector switch to the reset position and hold for at least 5 seconds If the boiler does not relight or the code is displayed regularly contact your instal...

Page 9: ... check online at www corgi gas safety com The boiler meets the requirements of Statutory Instrument The Boiler Efficiency Regulations 1993 No 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production cer...

Page 10: ...c hot water will operate on demand To set the time of day Turn the timer outer bezel clockwise to align the pointer with the correct time to the nearest 15 minutes ensuring that A M P M is considered Do not at any time attempt to turn the bezel anti clockwise To set the timed heating program Decide which times of the day the central heating is required The heating will operate when the white tappe...

Page 11: ...ed until the fault has been corrected by a competent person Warning Gas Tap Heating Flow Heating Return and Mains Water Inlet Isolating Valves Fig 9 Fig 10 In an Emergency If a water or gas leak occurs or is suspected the boiler can be isolated at the inlet valves as follows 1 Using a suitable open ended spanner turn the square nut on the gas tap through 90 1 4 turn to isolate the gas supply at th...

Page 12: ... that you may need Our contact centre is open Monday to Friday 8am 6pm weekends and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling heateam it would be helpful if you could have the following information to hand 1 boiler serial number see opposite 2 boiler make and model number 3 Your installer name and address details 4 Proof of purchase if you do not have the boil...

Reviews: