24
912.807.1 - GB
INSTALLATION AND OPERATING MANUAL
The
SIRIUS SAT
module can be remote controlled using the
ECO CRONO
climate adjustor.
Connect the ECO CRONO climate adjustor to the ambient thermostat 1 terminals on the electronic board, as described
below:
r "DDFTTUIFFMFDUSJDBMDPNQPOFOUTBTEFTDSJCFEJOQBSBHSBQI
r 3FNPWFUIFKVNQFSPOUIFFMFDUSPOJDCPBSEUFSNJOBMT $/"# TFFXJSJOHEJBHSBNTJOf
r $POOFDUBUXPXJSFDBCMFUPUIF&$0$30/0UFS056TFBIBSNPOJTFEDBCMFi)"3)77'uY
mm2 with a maximum diameter of 8 mm.
r *OUSPEVDFUIFUXPXJSFDBCMFUISPVHIUIFHSPNNFUTPGUIFFMFDUSJDBMCPYBOEDPOOFDUJUUPUIFFMFDUSPOJDCPBSEUFSNJOBMT
(CN7: A-B). Also consult the manual supplied with the ECO CRONO.
With this device connected, the GREEN LED DL2 on the electronic board flashes at 5s intervals. The instructions supplied
with the ECO CRONO climate adjuster also include the information required to:
r 1SPHSBNNFVTFSTFUUBCMFQBSBNFUFST
r 1SPHSBNNFàUUFSTFUUBCMFQBSBNFUFST
r *OTUBMMBUJPO
16. CONNECTING THE CLIMATE ADJUSTER: ECO CRONO (accessory available on request)
Attention: only make adjustments to the electronic board after disconnecting the power supply (see §10: access
to live components)
The following adjustment can be made on the electronic board
:
TR = Heating temperature adjustment potentiometer (CH1)
Adjusts the heating delivery temperature according to the set climate curve.
TR temperature range: 25 ÷ 80°C
(see climate curve selection table)
With the external probe, this device acts as a maximum temperature limiting device.
For dual-zone models
(RA2Z),
heating temperature adjustment only applies to the mixed zone. The other zone works
directly with the temperature of the inlet water from the centralised system.
17. ELECTRONIC BOARD ADJUSTMENT
0904_2501 / CR_0014
Figure 14 A: Heating potentiometer
HEATING POTENTIOMETER
MEDIUM
CLIMATE CURVE
LOW
CLIMATE CURVE
HIGH
CLIMATE CURVE