11.2 To remove the complete burner unit.
1.
Remove the firefront and place in a safe position.
2.
Remove the ceramic fuel effect.
3.
Close the valve in the inlet ‘T’ connector / elbow.
4.
Disconnect the appliance from the inlet ‘T’ connector.
5.
Remove the front leg fastening screw. This is located to the left of the control knob.
6.
Lift the burner out of the fireplace opening.
7.
Replace in the reverse order.
11.3 To remove the pilot unit.
1.
Remove the burner unit (See section 11.2).
2.
Detach the pilot pipe from the pilot unit.
3.
Detach the thermocouple from the gas valve.
4.
Detach the electrode lead from the underside of the
electrode tab.
5.
Remove the two screws securing the pilot unit (See
figure 20).
6.
Refit in the reverse order.
Note: The pilot unit is an atmosphere sensing device. It must be replaced as a
whole assembly. Its individual components are not separately
replaceable.
11.4 To remove the gas valve.
(See figure 21).
1.
Remove the burner unit (See section 11.2).
2.
If lying the burner on its back, ensure that the work surface is suitably protected.
This will avoid damage to the work surface. Turn the burner unit upside down.
Detach the thermocouple from the tap.
3.
Detach the pilot pipe from the tap.
4.
Detach the inlet pipe.
5.
Detach the injector pipe.
6.
Detach the electrode lead from the
base of the electrode.
7.
Remove the control knob by pulling
forward.
8.
Remove the thermocouple by
unscrewing the thermocouple nut at
the gas valve.
9.
Remove the hexagonal nut securing
the gas valve to the mounting bracket.
10.
Remove the gas valve.
11.
Refit in the reverse order.
Page 27
© Baxi Heating U.K. Limited 2009.
Figure 20. Pilot unit removal
Figure 21. Gas valve (Viewed from rear
with burner turned over)
INSTALLER GUIDE