3. APPLIANCE DATA AND EFFICIENCY
3.1 General information.
*When converted using kit 0595211
3.2 Efficiency.
There are no specific thermal efficiency requirements appropriate to this type of
appliance as they are intended for decorative purposes only. For the purposes of SAP
the efficiency is classed as 20% for use in the Space Heating Requirements
calculation, see Table 4a of SAP.
Page 9
© Baxi Heating U.K. Limited 2009.
Gas
Natural (G20)
Propane (G31) *
Inlet Pressure
20 mbar
37 mbar
Input - Max. (Gross)
6.85 kW (23,400 Btu/h)
6.7 kW (22,860 Btu/h)
Input - Min. (Gross)
2.3 kW (7,850 Btu/h)
4.0 kW (13,650 Btu/h)
Burner Test Pressure (Cold)
20.0 ± 1.0mbar
(8.0 ± 0.4in w.g.)
37.0 ± 1.0mbar
(14.85 ± 0.4in w.g.)
Gas Connection
8mm pipe
8mm pipe
Burner Injector
Cat 82 - 074
Size 132
Pilot & Atmosphere Sensing
Device
Copreci Ref. O.D.S
21500/166
Copreci Ref. O.D.S
21500/166 Fitted with RBM
180 -02 injector
Ignition
Integral Piezo Spark
Integral Piezo Spark
Aeration
Factory set
Non-adjustable
INSTALLER GUIDE