7.
This appliance is supplied with a rear ceramic
support bracket. Fit this using two screws supplied
(See figure 13).
8.
This appliance is supplied with a flue restrictor for
use where the flue draught is excessive. The
restrictor must NOT be fitted where a precast flue or
a flue liner is used. For all other installations the
restrictor should be fitted. There may however, be
certain exceptional circumstances where fitting the
restrictor causes the fire to fail the spillage test. In
such cases the restrictor will have to be removed.
After removal conduct the spillage check again.
The restrictor is packed loose with the appliance
and is fixed with three screws (See figure 14).
9.
There is a length of self adhesive foam seal
supplied with the fire. This will need to be fitted to
the outer rear edges of the side and top flanges of
the convection box. Cut a 485mm length of foam
seal. Be careful not to stretch the seal when
measuring. Remove the protective backing from
the foam seal and fit this to the rear of the top
flange (See figure 15). Cut two 580mm lengths.
Fit these to the rear outer edges of the side
flanges. Ensure that there is no gap between the
foam seals where they meet at the top flange
(See figure 15).
Page 21
©
Baxi Heating U.K. Limited 2010.
Figure 15. Fitting the foam seal
Figure 14. Flue restrictor
Figure 13. Fitting the rear
ceramic support.
INSTALLER GUIDE