CERAMIC FUEL BED REFITTING
The installer and owner guide for the ceramic fuel effect is separate from this guide.
The installer may have attached it to this guide or placed it inside. It is important that
the installer and owner guide for the ceramic fuel effect is followed correctly. If
replacing the ceramic fuel effect, where a new guide is supplied, follow the installer
and owner guide supplied with the replacement fuel effect.
Keep the replacement installer and owner guide with this owner guide for future
reference.
MAINTENANCE
Battery replacement.
This appliance requires one 9V PP3 Ever
Ready Silver Seal (or equivalent) battery.
Fit the new battery firmly to the connections on
the ignition block (See figure 4). The +ve and
-ve terminal locations are shown on the battery
housing.
Regular maintenance.
In order to achieve and maintain high levels of
personal safety and performance efficiency, it
is essential that the opening at the back of the
fire and the flue are kept clear of any form of
obstruction. It is possible that deposits of mortar or soot could fall and accumulate
causing the flue to be blocked or restricted and so preventing proper clearance of
dangerous exhaust fumes.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue
and pipework which is situated in a tenant’s premises checked for safety at least
every twelve months by a competent person (In the UK a GAS SAFE REGISTER
engineer, Outside of the UK a CORGI or GAS SAFE REGISTER engineer).
We recommend that all gas appliances and their flues, wherever situated, are
checked annually.
Page 45
©
Baxi Heating U.K. Limited 2010.
OWNER GUIDE
Figure 4. Battery fitting