Page 19
©
Baxi Heating U.K. Limited 2010.
6. IGNITION CHECK
Before attempting to install, it is worth checking that the
ignition system performs satisfactorily.
Set the control knob to the off position.
Depress the control knob and rotate it anticlockwise to
the pilot ignition position. A 'click' will be heard as the
integral piezo operates. A spark should be seen
between the electrode and pilot tip. If there is no spark
check the following: -
Ensure that the electrode lead is connected to the
terminal at the base of the electrode.
If the above is correct, check for damage to the
electrode lead.
7. GAS SUPPLY CONNECTION
A nut and olive are provided for an 8mm pipe inlet connection to the ‘T’ connector at
the bottom front of the appliance. The ‘T’ connector can be rotated to allow a
connection from any direction and includes a valve for isolating the gas supply and a
pressure test point.
The supply pipe must be rigid material. Flexible pipe must not be used.
Concealed supply pipe connection
If a concealed connection from inside the fireplace is required then
,
before the
appliance is fitted into the fireplace
it will be necessary to extend the supply line so
that it will project through the hole in the back of the convection box and run to the ‘T’
connector at the front. The pipe run from the supply line up to the rear opening in the
convection box must be kept away from the area which will be taken by the
convection box when it is installed (See figure 4).
Note that the centre of the appliance inlet ‘T’ connector is 25mm above the fireplace
floor. The inlet ‘T’ connector should be fitted to the supply pipe at this stage.
INSTALLER GUIDE
Figure 8. Ignition operation