6.
This appliance is supplied with a rear ceramic
support bracket. Fit this using two screws
supplied (See figure 12).
7.
This appliance is supplied with a flue restrictor
for use where the flue draught is excessive. The
restrictor must NOT be fitted where a precast flue
or a flue liner is used. For all other installations
the restrictor should be fitted. There may
however, be certain exceptional circumstances
where fitting the restrictor causes the fire to fail
the spillage test. In such cases the restrictor will
have to be removed. After removal conduct the
spillage check again.
The restrictor is packed loose with the appliance
and is fixed with three screws (See figure 13).
8.
There is a length of self adhesive foam seal
supplied with the fire. This will need to be fitted
to the outer rear edges of the side and top
flanges of the convection box. Cut a 485mm
length of foam seal. Be careful not to stretch
the seal when measuring. Remove the
protective backing from the foam seal and fit
this to the rear of the top flange (See figure 14).
Cut two 580mm lengths. Fit these to the rear
outer edges of the side flanges. Ensure that
there is no gap between the foam seals where
they meet at the top flange (See figure 14).
Page 21
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Figure 14. Fitting the foam seal
Figure 13. Flue restrictor
Figure 12. Fitting the rear ceramic
support.