9. CONVECTION BOX INSTALLATION
9.1 Method 1 - Front fixing to fireplace surround.
1.
Make sure that the fireplace front surround area is sound enough to take the fibre
plugs and woodscrews. If necessary, make sound with suitable cement.
2.
Place the convection box centrally in the fireplace in the position in which it is to be
permanently installed. If a concealed connection is being used, insert the convection
box into the fireplace feeding the supply pipe through the pierced hole in the rear
grommet.
3.
Mark the fireplace front surround through
the four fixing holes in the side flanges of the
convection box (See figure 15).
4.
Remove the convection box. Drill four
holes in the fireplace front surround at the
marked positions using a suitably sized drill
bit for the wall plugs supplied.
5.
Insert a fibre plug into each hole.
6.
Place the convection box back in position
in the fireplace.
7.
Fit a woodscrew through each hole in the
convection box flanges and tighten to seal
the box to the fireplace surround.
9.2 Method 2 - Cable retention and floor fixing.
1.
Make sure that the relevant areas at the fireplace back or floor are sound enough
to take the eyebolts and screws. If these areas have deteriorated due to prolonged
use they should be made sound with suitable cement.
2.
Drill four holes in the rear wall of the fireplace for the eyebolt plugs. The holes
should be drilled within the range of positions shown in figure 16 using a suitably
sized drill bit for the wall plugs supplied. The holes should be equidistant each side of
the centre line of the fireplace to ensure that the appliance finishes centrally in the
opening when tension is applied to the cables.
3.
Insert a fibre plug into each hole. Use the fibre plugs supplied with this appliance -
Never use plastic plugs instead of the fibre plugs supplied
.
Screw the eyebolts
into the plugs. Make sure that the bolts are secure.
4.
Place the convection box unit close to the fireplace but allow sufficient access into
the fireplace opening so that the cables can be threaded through the eyebolts and
returned through the back of the convection box. If a concealed connection is being
used, insert the convection box into the fireplace feeding the supply pipe through the
pierced hole in the rear grommet.