5.
The convection box has two
holes at each side of the
convected air opening. Insert
one end of each cable (one
cable each side) from the back
through the lower of the two
holes and return the end through
the upper of the holes (See
figure 17). Give the cables a pull
so that they grip against the
convection box flanges.
6.
Thread the cables through the
eyebolts. Return the cables
through the holes near the
bottom of the convection box
back panel (See figure18)
(For
precast or clay block flue
systems return the cables
through the slotted holes in
the side of the convection
box)
.
7.
Place the convection box fully
back into the fireplace opening
so that it is sealed against the
fireplace front surround.
Page 23
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Figure 18. Cable route
Figure 17. Upper cable
retention
Figure 16. Eyebolt positions