Do
provide a suitable guard that complies with BS 8423 for the protection of young
children, the elderly, the infirm and pet animals. (Although this fire conforms to all the
applicable standards, it is a heating appliance and certain parts of its surface will
become hot).
Do
wait three minutes before attempting to relight if the fire is switched off or the
flames are extinguished for any reason. (Your fire is fitted with a safety device that will
automatically shut off the gas supply to the fire if, for any reason, the flames go out).
Do
get advice about the suitability of any wall covering near your fire. Soft wall
coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily affected
by heat. They may, therefore, scorch or become discoloured when close to a heating
appliance. Please bear this in mind whenever you are considering redecorating.
Do
provide a minimum side clearance as detailed below:
The minimum allowable distance from the outside of the fascia to a corner wall having
combustible material or any other combustible surface which projects beyond the
front of the appliance is 100mm.
A 10mm access clearance from a non-combustible surface is necessary at both
sides.
Don’t
hang clothing, towels or any other fabrics over the fire.
Don’t
add any extra fuel effect pieces above the number stated in the installer and
owner guide supplied with the ceramic fuel effect. The installer may have attached it
to this guide or placed it inside. Adding extra fuel effect pieces could cause a safety
hazard and consequent health hazards.
Don’t
put paper or any other material on the fire.
Don’t
place any combustible material (rugs, carpet, plastic tiles, etc.) on the hearth.
Don’t
attempt to clean or service the fire until it has been switched off and allowed to
cool completely.
GAS CONSUMPTION
Model 951
Has a maximum natural gas input of 6.85kW (Gross)
Has a maximum natural gas output of 3.75kW
Has a minimum natural gas input of 2.3kW (Gross)
Has a minimum natural gas output of 1.15kW
Model 951 when converted using kit number 0595211
Has a maximum propane gas input of 6.7kW (Gross)
Has a maximum propane gas output of 3.95kW
Has a minimum propane gas input of 4.0kW (Gross)
Has a minimum propane gas output of 2.35kW
Page 38
©
Baxi Heating U.K. Limited 2010.
OWNER GUIDE