2. APPLIANCE DATA AND EFFICIENCY
2.1 General information.
*
When converted using kit 0595211.
The appliance information label is located on a ‘pivot’ plate at the base of the fire.
This can be seen by pulling on the raised tab.
2.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below:
Model
Efficiency % (Gross)
951 58
951 when converted to LPG.
61
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
Page 8
©
Baxi Heating U.K. Limited 2010.
Gas
Natural (G20)
Propane (G31) *
Inlet Pressure
20mbar
37mbar
Input - Max. (Gross)
6.85kW (23,400 Btu/h)
6.7kW (22,860 Btu/h)
Input - Min. (Gross)
2.3kW (7,850 Btu/h)
4.0kW (13,650 Btu/h)
Burner Test Pressure (Cold)
20.0 ± 1.0 mbar
(8.0 ± 0.4in w.g.)
37.0 ± 1.0 mbar
(14.85 ± 0.4in w.g.)
Gas Connection
8mm pipe
8mm pipe
Burner Injector
Cat 82 - 074
Size 132
Pilot & Atmosphere Sensing
Device
Copreci Ref. O.D.S
21500/166
Copreci Ref. O.D.S
21500/166 Fitted with RBM
180 -02 injector
Ignition
Integral Piezo Spark
Integral Piezo Spark
Aeration
Factory set.
Non-adjustable
INSTALLER GUIDE