Fig.15
MW-6000252-2
1
2
3
/
4
1. Install the outdoor unit sufficiently high off the ground to allow
condensates to be discharged correctly.
2. Ensure the base meets the following specifications:
Specifications
Reason
Maximum width equal to the width of the outdoor unit.
Height at least 200 mm greater then the average depth of the
covering of snow.
This helps to protect the exchanger from snow and prevent
the formation of ice during the defrosting operation.
Location as far as possible from the thoroughfare.
The condensates discharge may freeze, causing a potential
hazard (sheet of black ice).
3. If the outside temperatures drop below zero, take the necessary
precautions to prevent the risk of freezing in the evacuation pipes.
4. Place the outdoor units beside each other and not on top of each
other to prevent the condensates from the lower unit to freeze.
5.2.4
Selecting the location of the control panel
For ergonomic reasons, the control panel must be at eye level in a clean
room.
1. Select a room in the building according to the following
recommendations:
Avoid areas of excessive moisture or oil vapour (such as a kitchen
or bathroom),
Keep away from powerful electrical appliances to avoid any
interference.
2. Install the control panel against a wall at eye level in the chosen room.
Fig.16
MW-4000120-3