7.2.2
Install the domestic hot water tank to the wall with a
tripod
The tripod option: Réf. 89788949, is mandatory when the wall to be fitted
to is not strong enough to support the weight of a full domestic hot water
tank.
The installer is responsible for the type of mounting used and the
mechanical integrity of the assembly including the bracket selection.
The screws, dowels and washers necessary to mount the brackets to the
wall are not provided.
The mounting brackets are supplied in the polystyrene base of the
domestic hot water tank.
The Tripod option must be fitted to a flat and solid surface.
With a Tripod, the domestic hot water tank must be mounted to the wall
with the upper bracket to prevent any tipping.
1. Pre-position the Tripod taking into consideration the dimensions
indicated in the diagram below to position the domestic hot water tank
on the wall. The Tripod must be at 42 mm from the wall.
2. Select the position of the upper mounting bracket of the domestic hot
water tank, within the constraints of the wall being mounted to (cable
and pipe channels):
150L
Position of the upper
bracket
2 position options
The position of the lower bracket is not important, however, the lower
bracket must still be fixed to the domestic hot water tank for the
operations that follow.
3. Pre-fit to the wall with the screws protruding by at least 15 mm. The
M10 screws to use will depend on the type of wall. The screws must
be able to support the weight of the domestic hot water tank when it is
full of water.
Fig.31
150l
500
800
440
MW-2000634-1
250
200 mini
770
7 Installation
32
7689749 - v03 - 25112019