channel at the front of the radiant box.

Replace the dress guard. Locate the bottom of the dress guard in the two holes in the

bottom panel apron. Push the guard back so that the two spring projections at the top of
the guard engage in the slots under the front decorative canopy.

MAINTENANCE

Regular maintenance.

In order to achieve and maintain high levels of personal safety and performance
efficiency, it is essential that the opening at the back of the fire and the flue are kept
clear of any form of obstruction. It is possible that deposits of mortar or soot could fall
and accumulate causing the flue to be blocked or restricted and so preventing proper
clearance of dangerous exhaust fumes.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue
and pipework which is situated in a tenant’s premises checked for safety at least every
twelve months by a competent person (In the U.K., a CORGI registered installer).
We recommend that all gas appliances and their flues, wherever situated, are checked
annually.

Servicing.

If you require your fire to be serviced, please contact British Gas or Scottish Gas

TELEPHONE 0845 950 0400 

and please quote the following details: 

Model name and number.
Appliance serial number (To be found on a label near the bottom left side of the 
fascia). 

If you wish to replace any radiants, spare parts are available nationwide via the 

interpart stockist network

’. For your local stockist consult Yellow pages under 

Central Heating.

Page 9

OWNER GUIDE

Summary of Contents for churchill II 347

Page 1: ...0 THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY Manufactured exclusively for British Gas Scottish Gas by Valor Heating For Service Phone 0845 950 0400 Baxi Heating U K Ltd CHURCHILL II Radiant Convector Gas Fire Model 347 G C Number 32 032 62 ...

Page 2: ...r is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation The manufacturer is a CORGI registered company This gas fire must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should not be fitted directly on to a carpet Valor Heating Erdington Birmingham B24 9QP w...

Page 3: ...l and local regulations in force Do have the chimney swept prior to installation if it was previously used for solid fuel Do have the fire installed in accordance with the installation instructions Do allow a minimum clearance of 95mm from the top of the appliance fascia to the underside of any shelf whether it is made from combustible or non combustible materials This clearance is necessary to al...

Page 4: ... get advice about the suitability of any wall covering near your fire Soft wall coverings e g embossed vinyl etc which have a raised pattern are easily affected by heat They may therefore scorch or become discoloured when close to a heating appliance Please bear this in mind whenever you are considering redecorating Do provide a minimum clearance of 48mm between the fascia sides and any corner wal...

Page 5: ...ON Has a maximum natural gas input of 5 6kW Gross Has a maximum natural gas output of 4 0kW Has a minimum natural gas input of 1 57kW Gross Has a minimum natural gas output of 1 0kW Page 5 OWNER GUIDE Figure 1 Dimensions and clearances ...

Page 6: ... to relight To light the fire The control is shown in figure 2 Depress the control knob and turn anticlockwise towards the 1 position A spark should be generated at the pilot while turning The spark should ignite the pilot If it does not keeping the knob depressed continue to turn the knob anticlockwise A second spark should ignite the pilot The pilot flame can be seen through the opening immediat...

Page 7: ...t side of the brass handle See figure 3 When the pilot is alight keep the knob depressed for about ten seconds to allow the flame sensing probe to warm up before setting to your preferred heat level For your own convenience have the heater serviced as soon as possible Page 7 OWNER GUIDE Figure 3 Control Knob Position Radiants Condition 2 Centre radiants on low Outer radiants off The right hand cen...

Page 8: ...lacement radiant Ask for part number 5110472 Turn the fire off and allow it to cool before attempting to remove the radiants Remove the dress guard by pressing down the two hooks at the top Tilt the guard forward and lift out Lift the radiant upward to clear the metal retaining bar then pull out bottom first Fit the new radiant by inserting its top under the top lip of the radiant box then swing t...

Page 9: ...ng proper clearance of dangerous exhaust fumes In the United Kingdom it is the law that a landlord must have any gas appliance flue and pipework which is situated in a tenant s premises checked for safety at least every twelve months by a competent person In the U K a CORGI registered installer We recommend that all gas appliances and their flues wherever situated are checked annually Servicing If...

Reviews: