Supplied By www.heating spares.co Tel. 0161 620 6677
Ebony Super
Baxi Heating Ltd.
page 3
Appliance Details – Page 3
Dimensions
HEIGHT
WIDTH
DEPTH
INPUT
OUTPUT
SETTING PRESSURE
(COLD)
GAS
ELECTRICAL
(MAIN INPUT)
THERMOCOUPLE
(OUTPUT)
RESISTOR
BURNER
PILOT IGNITION
WEIGHT
Projection in room
706mm (27 13/16 in)
750mm (29 ½ in)
326mm (12 13/16 in)
High - 5.42kW (18,500 Btu/h)
Low - 2.10kW (7,200Btu/h)
High - 3.47kW (11,840 Btu/h)
14.1 mbar± 1.0mbar
5.6in w.g. ± 0.4in w.g.
Natural Gas
230 volts ~ 50 Hz - 3A - 120W
9.4 to 13mV
68 ohms
Aerated - Duplex
Piezo Unit - Spark Gap
2.5mm - 4.0mm
40kg (88 lbs)
B.S. CODES OF PRACTICE
HEIGHT FROM HEARTH TO TOP OF FLUE SPIGOT
BS 6891
Gas Installation
489mm (19 ¼ in)
BS 5871 :Part 1
Installation of Gas Fires,
Convectors and Fire/Back Boilers
TAP
Duplex with rotary piezo
BS 5440:Part 1
Flues
and flame failure device
BS 5440:Part 2
Air Supply
operated by Oxy-pilot
BS 5258:Part 5
Fire Construction
BS 6332:Part 2
Fire Efficiency
BURNER INJECTORS
230
ELECTRICAL CONNECTION
THIS APPLIANCE MUST BE EARTHED
ALL EXTERNAL WIRING BETWEEN THE APPLIANCE AND
THE ELECTRICAL SUPPLY SHALL COMPLY WITH
CURRENT I.E.E. REGULATIONS.
The mains lead has the
following specifications: 16/0.2mm - 3 core PVC covered - PVC
insulated wire to BS 6500.
IMPORTANT:
Mains lead wires:
Green and yellow – Earth
Blue – Neutral
Brown – Live
FOR THE MAINS PLUG USE A 3AMP FUSE. The
appliance is supplied with approximately 3 metres of wire and a
mains plug. A longer cable may be fitted as follows:
Resistor
(a)
Remove the socket and plug from the cable supplied.
(b)
Re-assemble on the longer cable ensuring both
socket and plug are wired correctly.
If a different mains plug is used from the one supplied with
appliance proceed as follows:
The wire which is coloured green and yellow must be
connected to the terminal in the plug which is marked by
the letter ‘E’ or by the earth symbol or coloured green or
green and yellow. The wire which is coloured blue must be
connected to the terminal which is marked with the letter
N’ or coloured black. The wire which is coloured brown
must be connected to the terminal which is marked with
the letter ‘L’ or coloured red.