background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

Ebony Super

Baxi Heating Ltd.

page 3

Appliance Details – Page 3

Dimensions
HEIGHT
WIDTH
DEPTH

INPUT

OUTPUT

SETTING PRESSURE
(COLD)

GAS
ELECTRICAL
(MAIN INPUT)

THERMOCOUPLE
(OUTPUT)
RESISTOR
BURNER
PILOT IGNITION

WEIGHT

Projection in room
706mm (27 13/16 in)
750mm (29 ½ in)
326mm (12 13/16 in)

High - 5.42kW (18,500 Btu/h)
Low - 2.10kW (7,200Btu/h)
High - 3.47kW (11,840 Btu/h)

14.1 mbar± 1.0mbar
5.6in w.g. ± 0.4in w.g.

Natural Gas
230 volts ~ 50 Hz - 3A - 120W

9.4 to 13mV
68 ohms
Aerated - Duplex
Piezo Unit - Spark Gap
2.5mm - 4.0mm

40kg (88 lbs)

B.S. CODES OF PRACTICE

HEIGHT FROM HEARTH TO TOP OF FLUE SPIGOT

BS 6891

Gas Installation

489mm (19 ¼ in)

BS 5871 :Part 1

Installation of Gas Fires,
Convectors and Fire/Back Boilers

TAP

Duplex with rotary piezo

BS 5440:Part 1

Flues

and flame failure device

BS 5440:Part 2

Air Supply

operated by Oxy-pilot

BS 5258:Part 5

Fire Construction

BS 6332:Part 2

Fire Efficiency

BURNER INJECTORS

230

ELECTRICAL CONNECTION

THIS APPLIANCE MUST BE EARTHED

ALL EXTERNAL WIRING BETWEEN THE APPLIANCE AND
THE ELECTRICAL SUPPLY SHALL COMPLY WITH
CURRENT I.E.E. REGULATIONS.

 The mains lead has the

following specifications: 16/0.2mm - 3 core PVC covered - PVC
insulated wire to BS 6500.

IMPORTANT:

Mains lead wires:
Green and yellow – Earth
Blue – Neutral
Brown – Live

FOR THE MAINS PLUG USE A 3AMP FUSE. The
appliance is supplied with approximately 3 metres of wire and a
mains plug. A longer cable may be fitted as follows:
Resistor

(a)

Remove the socket and plug from the cable supplied.

(b)

Re-assemble on the longer cable ensuring both
socket and plug are wired correctly.

If a different mains plug is used from the one supplied with
appliance proceed as follows:

The wire which is coloured green and yellow must be
connected to the terminal in the plug which is marked by
the letter ‘E’ or by the earth symbol   or coloured green or
green and yellow. The wire which is coloured blue must be
connected to the terminal which is marked with the letter
N’ or coloured black. The wire which is coloured brown
must be connected to the terminal which is marked with
the letter ‘L’ or coloured red.

Summary of Contents for EBONY SUPER

Page 1: ...heating spares co Tel 0161 620 6677 Page 1 Please leave these Instructions with the User Baxi Ebony Super Gas Fire Comp No 236202 Issue 4 10 99 Installation and Servicing Instructions Baxi Ebony Super G C No 32 077 37 ...

Page 2: ...ndling these articles to ensure the release of dust or fibres is kept to a minimum To ensure that the release of fibres from these articles is kept to a minimum during installation and servicing it is recommended that a H E P A filtered vacuum is used to remove any dust soot or other debris accumulated in and around the appliance This should be performed before and after working on the installatio...

Page 3: ...CAL CONNECTION THIS APPLIANCE MUST BE EARTHED ALL EXTERNAL WIRING BETWEEN THE APPLIANCE AND THE ELECTRICAL SUPPLY SHALL COMPLY WITH CURRENT I E E REGULATIONS The mains lead has the following specifications 16 0 2mm 3 core PVC covered PVC insulated wire to BS 6500 IMPORTANT Mains lead wires Green and yellow Earth Blue Neutral Brown Live FOR THE MAINS PLUG USE A 3AMP FUSE The appliance is supplied w...

Page 4: ...attention DO NOT FIT THE FIRE SEEK EXPERT ADVICE HEARTH FIXING Fireplace or Surround a Fit the fire backing plate to the fire using the M5 x 8mm thread forming screws provided The backing plate may be screwed to the wall for extra support if necessary Fig 6 b Position the fire minus the outer case against the closure plate and determine the position of the gas connection c Adjust the feet to level...

Page 5: ... position and wait for 3 minutes before attempting to light the pilot again d Push in the control knob and turn fully anti clockwise Check that the ignition is satisfactory e Check the fire pressure with the control knob turned fully anti clockwise The pressure should be 14 1mbar 1 0mbar 5 6 in wg 0 4 in wg No adjustment is provided on the fire Turn the control knob to the OFF position Remove the ...

Page 6: ...ve the outer case for access to all controls a Pull off the control knob b Remove the cover panel under the front of the fire by grasping it firmly by its side edges and pulling forwards c Remove the two case securing screws Fig 7 d Lift the case away from the heat exchanger 2 Remove the glass front panel Fig 10 a Ensure that the glass front panel is cold b Slide the glass front panel retaining cl...

Page 7: ...Supplied By www heating spares co Tel 0161 620 6677 Ebony Super Baxi Heating Ltd page 7 Fit the Outer Case Page 7 ...

Page 8: ...fting it carefully away from the locating pins CAUTION The coal bed is extremely fragile and must be handled accordingly Gloves should be worn and any inhalation of the dust should be avoided Keep the coals away from children at all times Please read the Important Information Section on page 2 On re assembly ensure that the coal bed is correctly located over the locating pins BURNER Figs 10 11 and...

Page 9: ... Glass Frame Assembly 155 758 040955 C Knob Gas Tap Control 156 431 234551 D Flame Failure Device Gas Tap E05 653 242512 E Piezo Unit Vernitron 66111 393 734 042941 F Electro Magnet Unit E01 617 239413 G Injector F11 Cat 18 230 381 879 092133 H Burner Aeromatic Baxi Special 155 949 043210 I Oxy pilot Assembly 350mm SIT OP 9402 378 914 236204 J Lead Electrode 378 915 236199 K Coal Bed 156 429 23514...

Page 10: ...Supplied By www heating spares co Tel 0161 620 6677 Ebony Super Baxi Heating Ltd Page 10 Fault Finding Chart Page 10 11 BAXI EBONY SUPER Gas Type G20 Natural Gas Click here for Helplines ...

Reviews: