37
INST
ALLER Section (en)
7115196.01 (5-10/14)
TABLE 2
PARAMETERS - rpm
VENTURI
Ø (mm)
GAS NOZZLES
Ø (mm)
CO
2
Min
(%)
CO
2
Max
(%)
Max. CO
(ppm)
P60
**
P30 -
P61
**
P59
**
Boiler
model
Min. power
Max. power
Ignition power
G20
G31
G20
G31
G20
G31
G20-
G31
G20
G31
G20
G31
G20
G31
G20/G31
1.35
1500
1500
5000
4800
2300
3000
24
3.7
Q
2.95
Q
*8.5
*9.5
*9.0
*10
< 250
1.50
1500
1500
6650
6400
2300
3000
24
3.7
Q
2.95
Q
*8.5
*9.5
*9.0
*10
1420
1420
6750
6600
2000
2500
28
4.6
Q
3.45
Q
*9.0
*9.4
*9.0
*10.1
1.70
1270
1270
6450
6100
2100
2500
30
5.3
Q
Q
*8.5
*9.5
*9.0
*10
*
CO
2
with cover closed. Without cover (chamber open) the value is less than
*
*
value read on the boiler front panel display to multiply
x 10
(e.g.: 150 corresponds to 1500 rpm)
7RVLPSOLI\FDOLEUDWLRQRIWKHJDVYDOYHVHWWKH³FDOLEUDWLRQIXQFWLRQ´GLUHFWO\RQWKHERLOHUFRQWUROSDQHODVGHVFULEHGLQ
section 12.2.
)RUFDVFDGHGXFWVFKDQJHWKHSDUDPHWHU3LQFUHDVLQJWKHQXPEHURIIDQUHYROXWLRQVE\VHHWDEOH%LQFKDSWHU
16. ADJUSTMENT AND SAFETY DEVICES
The boiler has been designed in full compliance with European reference standards and in particular is equipped with the following:
Limit thermostat
7KDQNVWRDVHQVRUSODFHGRQWKH&+ÀRZOLQHWKLVWKHUPRVWDWLQWHUUXSWVWKHÀRZRIJDVWRWKHEXUQHULIWKHZDWHULQWKHSULPDU\
circuit overheats. Under such conditions the boiler is blocked and only after the fault has been eliminated can it be ignited again
by pressing
.
([FKDQJHUÀDQJHWKHUPRVWDW&
7KLV GHYLFH LV ORFDWHG RQ WKH H[FKDQJHU ÀDQJH DQG LQWHUUXSWV WKH ÀRZ RI JDV WR WKH EXUQHU LI WKH IURQW LQVXODWLRQ \LHOGV DQG
RYHUKHDWVWKHH[FKDQJHURUWKHÀDQJHJDVNHWGHYHORSVDIDXOW3UHVVWKHUHVHWEXWWRQRQWKHWKHUPRVWDWHOLPLQDWHWKHIDXOWDQG
then press the reset button on the boiler control panel.
It is forbidden to disable this safety device.
17&ÀXHVHQVRU
7KLVGHYLFHLVSRVLWLRQHGRQWKHIXPHVGXFW7KHHOHFWURQLFERDUGVWRSVJDVIURPÀRZLQJWRWKHEXUQHULQFDVHRIRYHUKHDWLQJ
Press
to re-establish normal operating conditions.
7KHDERYHUHVHWRSHUDWLRQLVRQO\SRVVLEOHLIWKHWHPSHUDWXUHLVOHVVWKDQ&
It is forbidden to disable this safety device
Flame ionisation detector
7KHÀDPHVHQVLQJHOHFWURGHJXDUDQWHHVVDIHW\RIRSHUDWLRQLQFDVHRIJDVIDLOXUHRULQFRPSOHWHLJQLWLRQRIWKHPDLQEXUQHU,Q
these conditions, the boiler blocks. Press
to re-establish normal operating conditions.
+\GUDXOLFSUHVVXUHVZLWFK
This device allows the main burner to be ignited only if system pressure is higher than 0.5 bars.
Pump post-circulation
The electronically-controlled pump post-circulation function lasts 3 minutes and is enabled, in the heating mode, if the ambient
thermostat causes the main burner to go out.
Summary of Contents for Luna Duo-Tec MP 1.35
Page 82: ...7115196 01 5 10 14 82 S E C T I O N A 20 ...
Page 86: ...7115196 01 5 10 14 86 S E C T I O N C ...
Page 87: ...87 S E C T I O N C 7115196 01 5 10 14 ...
Page 89: ...89 S E C T I O N E 7115196 01 5 10 14 MP 1 35 1 50 MP 1 60 MP 1 70 ...
Page 90: ...7115196 01 5 10 14 90 S E C T I O N E AGU 2 550 CR_0349 CR_0349 AVS 75 S E C T I O N F ...
Page 91: ...91 S E C T I O N E 7115196 01 5 10 14 CG_2482 Tmax 50 C S E C T I O N F ...