26
Parameter N
LUNA HT 280
LUNA HT 330
LUNA HT 1.120
LUNA HT 1.240
LUNA HT 1.280
H536
4900
4550
5650
5900
4550
H552
38
38
35
35
35
If the electronic circuit board is replaced, make sure that the parameters set are those specific to the
boiler model, as indicated in the documentation available from the authorised Service Centre.
Table 3
Parameter N.
H505
H507
H516
H532
H533
H536
H544
H545
H552
H584
H602
H603
H615
Description
Maximum temperature (
°
C) of the central heating circuit HC1 corresponding to:
-
the main circuit in systems with just one zone;
-
the circuit of the zone where the QAA73 temperature control device is installed
in case of systems with more than one high-temperature zone;
-
the high temperature zone circuit in mixed systems and if the SIEMENS
AGU2.500 accessory is used.
Maximum temperature (
°
C) of the central heating circuit HC2 of a system with
more than one zone, corresponding to the circuit of the low-temperature zone if
the SIEMENS AGU2.500 accessory is used.
Automatic Summer / Winter switching temperature (
°
C).
Selection of temperature curve of central heating circuit HC1 (see Graph 1)
Selection of temperature curve of central heating circuit HC2 (see Graph 1)
Selection of central heating power (N. of fan rpm)
Pump post-circulation time in central heating mode (min)
Burner operating pause time between two start-ups (s)
Hydraulic system setting (see instructions provided with the SIEMENS
AGU2.500 accessory)
Pump / three-way valve anti-blocking operating time (s)
Heat exchanger preheating holding time after operation in domestic hot water
mode (min)
Heat exchanger preheating holding time after operation in central heating mode
(min)
Programmable function:
-
“0” electricity supply to zone pump / valve and use of the SIEMENS
AGU2.500 accessory;
-
“1” electricity supply to a remote LPG gas valve;
-
“5” electricity supply to zone pump / valve in the absence of the SIEMENS
AGU2.500 accessory.
Only one of these functions can be selected.
Factory setting
80
70
20
15
15
See table 3
3
180
See table 3
10
0
0
5
The boiler parameters may only be modified by professionally qualified staff proceeding as follows:
a) press the , keys on the boiler’s front panel together for about 3 s until the parameter H90
appears on the display;
b) press the keys to select the parameter for modification;
c) press the and keys to modify the parameter;
d) press the key to exit the programming function.
e) when programming is finished, warning message E183 will blink for 3 seconds approx.
If the warning continues to blink or if other warnings are displayed, press the reset button
When warning message E153 appears, press the reset button a second time.
The following are the parameters generally used:
17. Setting the boiler
parameters